CALL US

+44 (0)1494 792602

Areas of application/material types specific to the measuring heads:

Application-specific measuring heads, which can be used with both measuring devices, are available for various areas of application.

This provides various possibilities for data acquisition and processing, which extend as far as the graphical display of the distribution of moisture in measurement objects. In many cases only this grid moisture measurement can really provide the necessary information with regard to the moisture content of objects.

Individual measurements can be carried out quickly with all moist sensors. The measuring devices are equipped with an energy-saving standby logic, with which you can switch on the measuring head circuitry for about half a second as required.

This rapid measurement option enables you to record many measured values in a short space of time.
Overview of the areas of application/material types specific to the measuring heads:
Microwave
measuring
head
R1 P R2 D S Endo
Wood Yes Yes Yes No Yes Yes
Building materials, brickwork Yes Yes Yes Yes Yes Yes
Bulk materials Yes Yes No No No Yes
Concrete No No No No Yes Yes
Planar materials Yes Yes No No No No
Ceramic materials No No Yes Yes Yes No
Plastics No No Yes Yes Yes No
Floors No No No No Yes Conditional
Rocks No No No No No Yes
Grain Yes Yes No No No No
Foodstuffs No No No Yes No No
Other materials on request

Characteristics of the available microwave measuring heads

Moist-R1Moist-PMoist-R2Moist-DMoist-SMoist-Endo
Radiating applicator for moisture measurements in the outer material layers.Radiating applicator for moisture measurements in the volume or core of a sample. Irregularities in the material can be compensated due to the large measurement volume.Stray field applicator for moisture measurements in the outer and central material layers.Radiating applicator for moisture measurements in the central material layers.Radiating applicator for moisture measurements in deep material layers. Primarily suited for relative measurements in very thick materials and structures.Penetration applicator for moisture measurements deep inside the measured object.

All measuring heads are powered by the Moist hand-held measuring device. The possibility of material-specific calibration enables exact and reproducible moisture measurements even under difficult usage conditions.

 

Technical data – Moist microwave measuring heads


Moist
microwave
measuring heads
           
Technical data Moist-R1 Moist-P Moist-R2 Moist-D Moist-S Moist-Endo
Depth of penetration (depending on material) up to 4 cm up to 30 cm up to 7 cm up to 11 cm up to 80 cm up to approx.
4 cm (radial)
Measured volume 20 cm³ 10 ... 15 litres 150 cm³ 2 litres max. 50 litres -
Material-specific calibration possible yes yes yes yes on request yes
Range of use (depending on material) 0 % < F
< 400 % (¹), 0 % < F < 80 % (²)
0 % < F
< 400 % (¹)
0 % < F
< 100 % (¹), 0 % < F < 50 % (²)
0 % < F
< 100 % (¹), 0 % < F < 50 % (²)
0 % < F
< 400 % (¹), 0 % < F < 80 % (²)
0 % < F < 10 % (even higher, depending on material)
Absolute accuracy 0.1 … 0.5 % attainable, depending on material 0.2 … 0.5 % attainable, depending on material 0.1 ... 0.5 % attainable, depending on material 0.2 … 0.5 % attainable, depending on material Not calibrated specific to material Material-specific – dependent on reference behaviour
Temperature range 0 ... 70 °C 0 ... 70 °C 0 ... 70 °C 0 ... 70 °C 0 ... 70 °C 0 ... 70 °C
Dimensions 130 x 50 mm,
250 g
130 x 50 mm,
250 g
130 x 50 mm,
250 g
130 x 50 mm,
250 g
130 x 50 mm,
250 g
130 x 50 mm, tube length
450 mm, 600 g